Cat S-FTP flertrådet Armering Grå

LanMarin® Cat 7A ARM AWG 23/7

Variant:

Individual and collective screened lan-cable for ship and offshore, galvanized steel wire armour, low smoke,
halogenfree and UV-resistant SHF1 jacket. The product is suitable for EMC-installations. It is tested according
to IEC 61156-5 for transmission characteristics up to 1 000 MHz - Horizontal floor wiring - Sectional specification. 
IEEE 802.3at-2009 Type 2 (PoE+). This cable can be used in rough environments.

Construction

Conductor
7 x 0.23 [mm²]
stranded
Bare Cu
AWG 23/7
Insulation
Foamskin PE
1.55 ± 0.05 [mm]
Screen
Individual
Al/Mylar
No. of pairs
4
Colour code
IEC
Individual Screen pairs
Al/Mylar tape
Screen
Tinned Cu-braid
≥ 60 [% coverage]
Inner jacket
SHF1
Ø = 9.0 [mm]
Armour
0.3 mm
Galvanized steel wire
braid
≥ 60 [% optical cover]
Outer Jacket
Grey
SHF1
O.D.
12.2 [mm]
Weight
120 [kg/km]
Jacket marking
NEK Kabel – Cat7A Marin armoured 4x2x23/7AWG – SHF1 
– IEC 60332-3-22 – DNV – Batch no– DD/MM/YY – ****m

Specifications

Operating temperature normal
-40 – +80 [°C]
Temperature @ installation
-20 – +60 [°C]
Dielectric strength
DC1kV for 1min.
Characteristic impedance
100 [Ω]
Conductor DC resistance
≤ 73.2 [Ω/km]
Resistance DC unbalance
≤ 5 [%]
Insulation resistance
≥ 5000 [MΩ x km]
(IEC 60189-1)
Power over Ethernet
IEEE 802.3at-2009
Type 2 (PoE+)
Rated voltage
≥ 80 [V]
Capacitance unbalance
≤ 160
[pF/100m at 1kHz]
(IEC 60189-1)
Velocity factor
70 [%]
Mutual capacitance
48
[nF/km]
Transmission speed
IEC 61156-5
Min. bending radius
5 [x outer diam]
Min. bending radius installed
10 [x outer diam]

Norms

Halogenfree, max content corrosive and toxic gases
IEC 60754-1 & IEC 60754-2
Material properties, insulation and sheath
IEC 60092-360
Design and testing standards
IEC 61156-5
Flame resistance
IEC 60332-3-22
Flame retardant
IEC 60332-1
Smoke emission
IEC 61034-2
≥ 60%
Oil and fuel resistant
IRM 902
4h @ 70°C
UV-resistant
UL 1581 (300H)
Certification
DNV
Part No.
1089658

Attenuation

Frequency (MHz) Attenuation Max. (dB/100m) Return Loss (dB/100m) NEXT (dB/100m) PS-NEXT (dB/100m) ELFEXT (dB(100m) PS-ELFEXT (dB/100m)
4 3.75 23.0 78.0 75.0 78.0 75.0
8 5.22 24.5 78.0 75.0 77.2 74.2
10 5.82 25.0 78.0 75.0 75.3 72.3
16 7.34 25.0 78.0 75.0 71.2 68.2
20 8.20 25.0 78.0 75.0 69.3 66.3
25 9.18 24.3 78.0 75.0 67.3 64.3
31.25 10.26 23.6 78.0 75.0 65.4 62.4
62.5 14.57 21.5 78.0 75.0 59.4 56.4
100 18.53 20.1 75.4 72.5 55.3 52.3
200 26.47 18.0 70.9 67.9 49.3 46.3
250 29.73 17.3 69.4 66.4 47.3 44.3
300 32.69 17.3 68.2 65.2 45.8 42.8
500 42.76 17.3 64.9 61.9 41.3 38.3
600 47.10 17.3 63.7 60.7 39.7 36.7
800 54.92 16.1 61.9 58.9 37.2 34.2
1000 61.93 15.1 60.4 57.4 35.3 32.3

Updated

Date Rev. Description
03.10.2023 1 Rated voltage