CAN Bus Marin 1x2x0.75mm², SHF1

CAN Bus Marin 1x2x0.75mm², SHF1

Variant:

Designed for CAN-Bus system for ships, according to the NMEA 2000 standard for transferring signals at 250 kbit/s. The cable, with its high anti-inferance ability and outstanding reliability is well suited for use in ships- and offshore installations.

Construction

Conductor
0,75 [mm²]
Flexible
tinned Cu
class 5
0.75mm² (24 x 0.20 mm)
Insulation
Foamskin PE
Ø=2,59±0,10 [mm]
No. of pairs
1
Colour code
white-blue
Filler
PP
Screen
Al/Mylar
Screen 2
Tinned Cu braid
>80 [% optical coverage]
Jacket
Black
SHF1
, thickness app. 1,05mm
O.D.
8,5 ± 0,40 [mm]
Jacket marking
NEK Kabel AS - CAN Bus Marin 1x2x0.75mm² 
- IEC 60332-3-22-Cat.A - "batch" - DD-MM-YY - ****M

Specifications

Operating temperature normal
-40 - +80 [°C]
Temperature @ installation
-20 - +60 [°C]
Operating voltage
100
[V]
Test Voltage
1
[kV-DC]
Conductor resistance
≤ 26 [Ω/km]
Insulation resistance
≥ 1 [GΩ x km]
Capacitance
40 [pF/m @ 800-1000MHz]
Impedance
120±12
[Ω @ 1MHz]
Attenuation
≤ 25 [dB/km@1MHz]
Transmission speed
- 500 kbit/s - 100 m (328 ft)
- 250 kbit/s - 250 m (820 ft)
Min. bending radius
10 [x outer diam]
Min. bending radius flexible
20 [x outer diam]

Norms

Halogenfree, max content corrosive and toxic gases
IEC 60754-1 and IEC 60754-2
Material properties, insulation and sheath
IEC 60092-360
Flame resistance
IEC 60332-3-22
Flame retardant
IEC 60332-1-2
Smoke emission
IEC 61034-2
, (≥ 60%)
Oil and fuel resistant
IRM 902
23ºC / 7 days, 70°C / 4h
UV-resistant
UL 1581 seksjon 1200
Certification
DNV
Part No.
1097090