RF-LLX-CL 1/2" 50

RF-LLX-CL 1/2" SHF1

Variant:

Radiating coaxial cable for tunnels, ships, buildings and other closed areas.

Construction coaxial

Conductor
Cu-clad Al
4.8 ± 0.2 [mm]
Dielectric
Foamed PE
12.0 ± 0.5 [mm]
Screen
Slotted Cu-tube
13.9 ± 0.5 [mm]
Jacket
Black
SHF1
UV-resistant
Outer diam.
16.0 ± 0.5 [mm]
Weight
248 [kg/km]

Specifications

Operating temperature normal
-20 – +70 [°C]
Temperature @ installation
-20 – +50 [°C]
Characteristic impedance
50 ± 2 [Ω]
Insulation resistance
5000 [MΩ x km]
Tensile strength
1130
[N]
Velocity factor
88 [%]
Min. bending radius
80 [mm]
Min. bending radius @ installation
125
[mm]

Norms

Halogenfree, max content corrosive and toxic gases
IEC 60754-1 & IEC 60754-2
Material properties, insulation and sheath
IEC 60092-360 (359)
, NEK 606
Design and testing standards
IEC 60096-0-1 Ed 3
EN 50288-1
Flame resistance
IEC 60332-3-22 Cat.A , IEC 60332-3-24 Cat.C
Flame retardant
IEC 60332-1-2
Weather resistant
ASTM G 154
Smoke emission
IEC 61034-2
Oil and fuel resistant
IEC 60811-2-1
Mineral Oils, IRM 902: 23ºC / 7 days, 70°C / 4h
Diesel,          IRM 903: 23ºC / 7 days, 70°C / 4h
UV-resistant
ASTM G 154
CPR classification
Dca-s1,d2,a1
Certification
DNV
Part No.
1092479
NEK offers connectors for RF-LLX-CL 1/2":
Female part no. 65443

Attenuation

Frequency [MHz] Attenuation [dB/100m ±5%] Coupling loss 95% [dB±10]
150 3.4 78
450 6.6 80
700 7.7 80
900 8.3 82
1800 13.7 88
1900 13.6 82
2200 15.4 85
2400 16.0 87
2600 16.8 82
3000 18.2 88
3500 19.9 85
3600 22.8 85

VSWR

Frequency [MHz] -
260 – 480 ≤ 1.30
820 – 960 ≤ 1.30
1700 – 1860 ≤ 1.30
1900 – 2050 ≤ 1.30
2100 – 2200 ≤ 1.30
2300 – 2500 ≤ 1.30
2500 – 2700 ≤ 1.30
3400 – 3600 ≤ 1.35

Updated

Date Rev. Description
20.04.2020 1 Picture
15.05.2020 2 VSWR
29.05.2020 3 Attenuation
01.06.2022 4 Weight and DNV-GL
22.12.2023 5 Norms
23.04.2025 6 Attenuation
03.03.2026 7 Construction and attenuation