High performance offshore LAN cable with solid conductors, AWG 23/1. Also designed as fire resistant communication cable
for car and railway tunnels. Compliant with the category 7 standards, requiring bandwidths up to 600 MHz. Foil screened pairs
with an overall tinned copper braid. Tested for high-frequency and transmission measurements for class F-link.
Female Modular plug can be connected to this cable. IEEE 802.3at-2009 Type 2 (PoE+). This cable can be used in rough environments.
Construction
Solid
Bare Cu
0.58 [mm]
AWG 23/1
Tinned Cu
solid, 0.4 [mm]
PE
Mica tape
4
IEC 60189-2
Al-/polyester tape
100 % [coverage]
Tinned Cu-braid
diam. of strands: ≥0,10mm, density ≤ 55 %
Grey
LSZH
UV-resistant
SHF1
8.9 ± 0.5 [mm]
100 [kg/km]
NEK Kabel – LanMarin Cat 7 FIRE S/FTP 4x2xAWG23/1 SHF1 – IEC 60332-3-22A – IEC 60331-23 – batch no. **** – YY/MM/DD – ****m
Specifications
-40 – +90 [°C]
-15 – +50 [°C]
≤ 69.5 [Ω/km]
≥ 5000 [MΩ x km]
IEEE 802.3at-2009
Type 2 (PoE+)
≥ 80 [V]
55 [pF/m]
at 800 - 1000 Hz
100 ± 5
[Ω] @ 100MHz
20 [x outer diam.]
10 [x outer diam]
Norms
IEC 60754-1 & IEC 60754-2
IEC 60332-3-22
IEC 60332-1-2
IEC 60331-23 (180min) EN 50289-4-16 (180min)
IEC 61034-1 & IEC 61034-2
IEC 60811-404
IRM 902
NEK TS 606
ASTM D 2565 92A
DNV
1089665
Frequency (MHz) | Attenuation (dB/100m) | NEXT (dB) | PS-NEXT (dB) | ELFEXT (dB) | PS-ELFEXT (dB) | RL (dB) |
---|---|---|---|---|---|---|
4 | 3,7 | 78,0 | 75,0 | 78,0 | 75,0 | 23,0 |
10 | 5,9 | 78,0 | 75,0 | 75,3 | 72,3 | 25,0 |
16 | 7,4 | 78,0 | 75,0 | 71,2 | 68,2 | 25,0 |
31,25 | 10,4 | 78,0 | 75,0 | 65,4 | 62,4 | 20,1 |
62,5 | 14,9 | 75,5 | 72,5 | 59,4 | 56,4 | 18,9 |
100 | 19,0 | 72,4 | 69,4 | 55,3 | 52,3 | 18,0 |
150 | 23,6 | 69,8 | 66,8 | 51,8 | 48,8 | 17,3 |
200 | 27,5 | 67,9 | 64,9 | 49,3 | 46,3 | 17,3 |
250 | 31,0 | 66,4 | 63,4 | 47,3 | 44,3 | 17,3 |
300 | 34,2 | 65,2 | 62,2 | 45,8 | 42,8 | 17,3 |
400 | 40,0 | 63,4 | 60,4 | 43,3 | 40,3 | 17,3 |
500 | 45,3 | 61,9 | 58,9 | 41,3 | 38,3 | 17,3 |
600 | 50,1 | 60,7 | 57,7 | 39,7 | 36,7 | 17,3 |
Updated
Date | Rev. | Description |
---|---|---|
19.01.21 | 1 | Updated Norms |
15.12.22 | 2 | Outer diam. |
03.10.2023 | 3 | Rated voltage |