CAN Bus Marin 1 pair, SHF2, 80ºC

CAN Bus Marin 1 pair, SHF2, 80ºC

Variant:

Designed for CAN Bus systems for ship and offshore according to the NVEA 200 standard for transferring signals at 250 kbits/s. The cable with its high anti-interference ability and outstanding reliability is well suited for industrial and offshore installations.

Construction

Conductor
Stranded
tinned Cu
0.75mm² (24 x 0.20 mm)
Protective conductor
Stranded tinned Cu
0,75 [mm²]
Insulation
Cellular PE
Ø = 2,95 ± 0,8 [mm]
No. of pairs
1
White / Blue
Individual Screen pairs
Al/Mylar tape
100% [coverage]
Screen
Al/mylar + tinned Cu-braid
>80 [% optical coverage]
Jacket
Black
SHF2
O.D.
8,70 ± 0,40 [mm]
Weight
203 [kg/km]

Specifications

Operating temperature normal
-40 – +80 [°C]
Operating voltage
100
[V]
Test Voltage
1000
[V]
-1min.
Conductor resistance
<26 [Ω/km]
Insulation resistance
>1 [GΩ x km]
Capacitance
40 [pF/m]
Impedance
120
[Ω]
± 10%
Attenuation
<25 dB/km at 1 MHz
Transmission speed
- 500 kbit/s - 100 m (328 ft)
- 250 kbit/s - 250 m (820 ft)
Min. bending radius flexible
20 [x outer diam]
Min. bending radius installed
10 [x outer diam]

Norms

Halogenfree, max content corrosive and toxic gases
IEC 60754-1 and IEC 60754-2
Material properties, insulation and sheath
IEC 60092-360
Flame resistance
IEC 60332-3-22 Cat.A
Flame retardant
IEC 60332-1-2
Ozone resistant
IEC 60811-2-1
300h
Smoke emission
IEC 61034-2
≥60%
Oil and fuel resistant
IRM 902
100°C x 24h
UV-resistant
UL 1581 (300H)
Certification
DNV
,   RMRS
Part No.
3020003

Updated

Date Rev. Description
12.06.2019 1 Part No.