Profibus Marin SHF2-Cu

Profibus DP Marin SHF2-MUD

Variant:

Profibus data cable, for use in ship, offshore and and industrial atomation systems.
Signal transmission from spearate sensors to control unit. 
The cable is halogen-free, flame-retardant, oil-resistant and UV-resistant.

Construction

Conductor
Stranded
tinned Cu
AWG 22/7
(7x0.254mm)
Insulation
Foam PE
Ø = 2.55 ± 0.05 [mm]
green, red
Filler
PP
No. of pairs
1
Screen
Al/Mylar
Screen 2
Tinned Cu braid
≥ 60 [% optical coverage]
Jacket
Black
SHF2
MUD
O.D.
7.8 ± 0.60 [mm]
Weight
95 [kg/km]
Jacket marking
NEK KABEL – PROFIBUS DP MARINE 1 x 2 x 0.35mm² –
SHF 2 – MUD –  IEC 60332-3-22 – DNV – <*****> – 
DD.MM.YYYY – ****M

Specifications

Operating temperature normal
-40 – +80 [°C]
Temperature @ installation
-20 – +60 [°C]
Characteristic impedance
@ 3-20 MHz: 150 ± 15Ω
@ 38,4 kHz:   185±18.5Ω
@ 9,6 kHz:      250 ± 25Ω
Conductor DC resistance
≤ 55 [Ω/km]
Insulation resistance
≥ 1 [GΩ x km]
Test voltage
1 [kV-DC 1 min.]
Capacitance
Nom. 30 [pF/m]
at 1kHz
Attenuation
≤ 45 dB/m @ 16 MHz
≤ 22 dB/m @ 4 MHz
≤ 5 dB/m @  38.4 MHz
≤ 3 dB/m @ 9.6 MHz
Min. bending radius
15 [x outer diam]

Norms

Halogenfree, max content corrosive and toxic gases
IEC 60754-1 & IEC 60754-2
Material properties, insulation and sheath
IEC 60092-360
Flame resistance
IEC 60332-3-22
Flame retardant
IEC 60332-1-2
Toxic gases max.
IEC 61034-2
≥ 60 %
Smoke emission
IEC 61034-1 & IEC 61034-2
Oil and fuel resistant
IRM 902 & IRM 903
100°C x 24h
MUD resistant
Calcium Bromide, 70℃×56d
EDC 95-11 base oil, 70℃×56d
UV-resistant
ASTM G 154
Certification
DNV
Prod.no.
1091039

Updated

Date Rev. Description
19.01.2017 1 Additional technical data
26.05.2025 2 Additional info