120 Ω Armoured BUS cable for industrial- and offshore environments. Tape and braided copper screens.
Data transmission in industrial environments.
Construction
Conductor
0.35 [mm²]
stranded
tinned Cu
AWG 22/7
(7 x 0.254 mm)
Insulation
Foam PE 1 pair: Ø = 2.03 ± 0.10 [mm] 4 core: Ø = 1.75 ± 0.10 [mm] 2 pair: Ø = 1.65 ± 0.10 [mm] 4 pair: Ø = 1.5 ± 0.05 [mm] 6 pair: Ø = 1.45 ± 0.05 [mm] 12 pair: Ø = 1.45 ± 0.05 [mm]
Colour code
See table
Filler
1 pair、2 pair、6 pairs、12 pairs yes: PP 4 core、2pairs、4 pair, none
Tape
1 pair、4 core、6 pairs、12 pairs, none 2 pairs、4 pairs, yes: Mylar tape
Screen
Al/Mylar
Screen 2
Tinned Cu braid
≥ 85 [% optical coverage]
Inner jacket
1P&4C: SHF1 Ø = 6.60 ± 0 .3 [mm] 2P: SHF1 Ø = 8.30 ± 0.4 [mm] 4P: SHF1 Ø = 9.30 ± 0 .5 [mm] 6P: SHF1 Ø = 10.4 ± 0.6 [mm] 12P: SHF1 Ø = 13.2 ± 0.7 [mm]
Armour alt.1
Galvanised steel wire braid
0.3 [mm] ≥ 60 % optical cover
Armour alt.2
Tinned Cu-braid
0.3 [mm] ≥ 60 % optical cover
Outer Jacket
Black or green
SHF1
thicknes app. 1.00 [mm]
O.D.
1P&4C: Ø = 9.8 ± 0.50 [mm] 2P: Ø = 11.60 ± 0 .60 [mm] 4P: Ø = 1 2 . 5 0 ± 0.60 [mm] 6P: Ø = 1 4 . 6 0 ± 0.70 [mm] 12P: Ø = 1 7 . 5 0 ± 0.80 [mm]
Jacket marking
4 cores: NEK Kabel – RS485 Industrial BUS – 4xAWG22/7 – GSWB – SHF1 – DNV – IEC 60332-3-22 – batch.no – dd/mm/yy – ****m 1 - 12 pairs: NEK Kabel – RS485 Industrial BUS – "n"x2xAWG22/7 – GSWB – SHF1 – DNV – IEC 60332-3-22 – batch.no – dd/mm/yy – ****m
Specifications
Operating temperature normal
-40 – +80 [°C]
Temperature @ installation
-20 – +60 [°C]
Dielectric strength
DC 2kV for 1min.
Characteristic impedance
120 ± 15 [Ω @ 1MHz]
Conductor resistance
≤ 55 [Ω/km]
Resistance unbalance
≤ 5 [%]
Insulation resistance
≥ 1 [GΩ x km]
Attenuation
≤ 20.0
[dB/km @ 1MHz]
Min. bending radius installed
8 [x outer diam]
Min. bending radius @ installation
15
[x outer diam]
Norms
Halogenfree, max content corrosive and toxic gases
IEC 60754-1 & IEC 60754-2
Material properties, insulation and sheath
IEC 60092-360 (359)
Design and testing standards
IEC 61158-2
Flame resistance
IEC 60332-3-22 Cat.A
Flame retardant
IEC 60332-1-2
Smoke emission
IEC 61034-2
Oil and fuel resistant
IEC 60811-2-1
IRM 902
23ºC / 7 days, 70°C / 4h
UV-resistant
UL 1581 (300H)
Certification
DNV
Pairs | Outer diam. [mm] | Weight [kg/km] | Art. no. |
---|---|---|---|
1 x 2 x AWG22/7 GSWB Black | 9.8 ± 0.5 | 143 | 2040006 |
2 x 2 x AWG22/7 GSWB Black | 9.8 ± 0.5 | 196 | 2040005 |
4 x AWG22/7 GSWB Black | 11.6 ± 0.6 | 150 | 2040010 |
4 x 2 x AWG22/7 GSWB Black | 10.3 ± 0.5 | 211 | 2040003 |
6 x 2 x AWG22/7 GSWB Black | 14.6 ± 0.7 | 309 | 2040011 |
12 x 2 x AWG22/7 GSWB Black | 17.5 ± 0.8 | 430 | 2040012 |
1 x 2 x AWG22/7 GSWB Green | 9.8 ± 0.5 | 143 | 2040013 |
4 x AWG22/7 GSWB Green | 9.8 ± 0.5 | 150 | 2040014 |
4 x 2 x AWG22/7 GSWB Green | 12.5 ± 0.5 | 211 | 2040015 |
Colour code
No. of cores | Colour code |
---|---|
1 - pair | White, blue |
2 - pairs | White/blue, blue; White/orange, orange |
4 - cores | Red, blue, brown, green |
4 - pairs | White/blue, blue, White/orange, orange, White/green, green, White/brown, brown |
6 - pairs | White/blue, blue; White/orange, orange White/green, green; White/brown, brown White/grey, grey; White/yellow, yellow |
12 - pairs | White/blue, blue; White/orange, orange White/green, green; White/brown, brown White/grey, grey; White/yellow, yellow Blue, orange; Blue, green Blue, brown; Blue,grey Blue, yellow; Orange, green |
Updated
Date | Rev. | Description |
---|---|---|
08.02.2022 | 0 | Created |
29.04.2025 | 1 | Adding 12 pairs |