RF-LLX-CL 1/2" 50 SHF2

RF-LLX-CL 1/2" 50 SHF2

Variant:

Radiating coaxial cable for tunnels, ships, buildings and other closed areas. Outer sheath SHF2, resistant to oil and grease.

Construction

Conductor
Copper-clad Al
4,8 ± 0,05 [mm]
Dielectricum
Foamed PE
12.10 ± 0.20 [mm]
Screen
Slotted corrugated copper tube
13.90 ± 0.25 [mm]
Outer Jacket
Black
MUD resistant SHF2
O.D.
16.5 ± 0.20 [mm]

Specifications

Operating temperature normal
-20 – +70 [°C]
Temperature @ installation
-20 – +50 [°C]
Characteristic impedance
50 ± 2 [Ω]
Insulation resistance
10000 [MΩ x km]
Tensile strength
1130
[N]
Velocity factor
0,88
Min. bending radius
80 [mm]
Min. bending radius @ installation
12
[mm]

Norms

Halogenfree, max content corrosive and toxic gases
IEC 60754-1 and IEC 60754-2
Material properties, insulation and sheath
IEC 60092-360 (359)
Design and testing standards
IEC 61196-1-100
IEC 60096-0-1 Ed 3
EN 50288-1
Flame resistance
IEC 60332-3-24 Cat.C
Flame retardant
IEC 60332-1-2
Smoke emission
IEC 61034-1 and IEC 61034-2
Oil and fuel resistant
IRM 902
100°C x 24h
MUD resistant
NEK TS 606
UV-resistant
ASTM G 154
ASTM D 4587
Certification
DNV
Prod.no
3031016
NEK offers:
ConMarin N-Female  PO: 65464
ConMarin N-Male      PO: 65402

Attenuation

Frequency [MHz] Attenuation [dB/100m ±5%] Coupling loss 95% [dB±10%]
150 3.40 62/78
450 6.60 70/80
900 9.50 71/82
1800 13.75 77/88
2200 15.40 76/85
2400 16.00 77/87

VSWR

Frequency [MHz] -
260 - 480 ≤ 1,25
820 - 960 ≤ 1,25
1700 - 1860 ≤ 1,25
1900 - 2050 ≤ 1,30
2100 - 2200 ≤ 1,30
2300 - 2400 ≤ 1,30