Radiating coaxial cable for tunnels, ships, buildings and other closed areas.
Construction coaxial
Conductor
Cu-clad Al
4.8 ± 0.2 [mm]
Dielectric
Foamed PE
12.0 ± 0.5 [mm]
Screen
Slotted Cu-tube
13.9 ± 0.5 [mm]
Jacket
Black
SHF1
UV-resistant
Outer diam.
16.0 ± 0.5 [mm]
Weight
248 [kg/km]
Specifications
Operating temperature normal
-20 – +70 [°C]
Temperature @ installation
-20 – +50 [°C]
Characteristic impedance
50 ± 2 [Ω]
Insulation resistance
5000 [MΩ x km]
Tensile strength
1130
[N]
Velocity factor
88 [%]
Min. bending radius
80 [mm]
Min. bending radius @ installation
125
[mm]
Norms
Halogenfree, max content corrosive and toxic gases
IEC 60754-1 & IEC 60754-2
Material properties, insulation and sheath
IEC 60092-360 (359)
, NEK 606
Design and testing standards
IEC 60096-0-1 Ed 3
EN 50288-1
Flame resistance
IEC 60332-3-22 Cat.A , IEC 60332-3-24 Cat.C
Flame retardant
IEC 60332-1-2
Weather resistant
ASTM G 154
Smoke emission
IEC 61034-2
Oil and fuel resistant
IEC 60811-2-1 Mineral Oils, IRM 902: 23ºC / 7 days, 70°C / 4h Diesel, IRM 903: 23ºC / 7 days, 70°C / 4h
UV-resistant
ASTM G 154
CPR classification
Dca-s1,d2,a1
Certification
DNV
Part No.
1092479
NEK offers connectors for RF-LLX-CL 1/2": Female part no. 65443
Attenuation
| Frequency [MHz] | Attenuation [dB/100m ±5%] | Coupling loss 95% [dB±10] |
|---|---|---|
| 150 | 3.4 | 78 |
| 450 | 6.6 | 80 |
| 700 | 7.7 | 80 |
| 900 | 8.3 | 82 |
| 1800 | 13.7 | 88 |
| 1900 | 13.6 | 82 |
| 2200 | 15.4 | 85 |
| 2400 | 16.0 | 87 |
| 2600 | 16.8 | 82 |
| 3000 | 18.2 | 88 |
| 3500 | 19.9 | 85 |
| 3600 | 22.8 | 85 |
VSWR
| Frequency [MHz] | - |
|---|---|
| 260 – 480 | ≤ 1.30 |
| 820 – 960 | ≤ 1.30 |
| 1700 – 1860 | ≤ 1.30 |
| 1900 – 2050 | ≤ 1.30 |
| 2100 – 2200 | ≤ 1.30 |
| 2300 – 2500 | ≤ 1.30 |
| 2500 – 2700 | ≤ 1.30 |
| 3400 – 3600 | ≤ 1.35 |
Updated
| Date | Rev. | Description |
|---|---|---|
| 20.04.2020 | 1 | Picture |
| 15.05.2020 | 2 | VSWR |
| 29.05.2020 | 3 | Attenuation |
| 01.06.2022 | 4 | Weight and DNV-GL |
| 22.12.2023 | 5 | Norms |
| 23.04.2025 | 6 | Attenuation |
| 03.03.2026 | 7 | Construction and attenuation |