Type RG 59 for ship- and offshore applications. Communication and video signals.
Stranded conductor is used for better protection against vibrations and cold bend.
Construction
Conductor                                    
                                    Stranded
Plain Cu
7 x 0.20 [mm]
Dielectricum                                    
                                    Low density PE
3.7 ± 0.10 [mm]
Screen                                    
                                    Al-polyester + Al tape
100 [% optical coverage]
Screen                                    
                                    Cu-braid
91 [% optical coverage]
Jacket                                    
                                    Black
SHF1
O.D.                                    
                                    6.20 ± 0.20 [mm]
Weight                                    
                                    52 [kg/km]
Jacket marking                                    
                                    NEK Kabel – RG 59 B/U Marine Flex – DD/MM/YY – batch **** – ****m
Specifications
Operating temperature normal                                    
                                    -40 – +80 [°C]
Characteristic impedance                                    
                                    75 ± 3 [Ω]
Braid Resistance                                    
                                    10 [Ω/km]
Conductor resistance                                    
                                    82 [Ω/km]
Test voltage                                    
                                    5 [kV]
Capacitance                                    
                                    67 [pF/m]
Velocity factor                                    
                                    0,66
Min. bending radius                                    
                                    5 [x outer diam]
Min. bending radius flexible                                    
                                    10 [x outer diam]
Norms
Halogenfree, max content corrosive and toxic gases                                    
                                    IEC 60754-1 & IEC 60754-2
Material properties, insulation and sheath                                    
                                    IEC 60092-359
Flame resistance                                    
                                    IEC 60332-3-22 Cat.A
Flame retardant                                    
                                    IEC 60332-1-2
Toxic gases max.                                    
                                    IEC 60092-359
Smoke emission                                    
                                    IEC 61034-2
Oil and fuel resistant                                    
                                    IEC 60811-3-1
UV-resistant                                    
                                    UL 1581, ISO 4892
Certification                                    
                                    DNV
Part No.                                    
                                    1092218
Attenuation nominal, max 105%
| Frequency MHz | Attenuation dB/100m | 
|---|---|
| 5 | 2.6 | 
| 10 | 3.3 | 
| 50 | 7.3 | 
| 100 | 10.8 | 
| 200 | 15.3 | 
| 400 | 21.9 | 
| 500 | 25.1 | 
| 600 | 27.4 | 
| 800 | 32.0 | 
| 1000 | 36.3 | 
| 1350 | 42.6 | 
| 1500 | 46.0 | 
| 1750 | 50.5 | 
| 2150 | 57.5 | 
| 2250 | 58.7 | 
| 2500 | 62.4 | 
| 2750 | 65.8 | 
| 3000 | 70.7 | 
Structural return loss
| MHz | dB | 
|---|---|
| 30 – 300 | > 30 | 
| 300 – 600 | > 25 | 
| 600 – 1000 | > 22 | 
| 1000 – 2000 | > 20 | 
| 2000 – 3000 | > 16 | 
Screen effectiveness IEC 61196-1
| MHz | dB | 
|---|---|
| 100 – 900 | > 90 | 
| 900 – 2000 | > 80 | 
| 2000 – 3000 | > 70 | 
Updated
| Date | Rev. | Description | 
|---|---|---|
| 03.05.2023 | 1 | Norms & attenuation | 

 
                