Reinforced cable for ship- and offshore LAN installations. The product is approved and available in alternative designs.
Solid or stranded conductors, and alternative galvanized steel wire or tinned copper armour braid. Both armours meets the
requirements for the EU EMC directive. Ethernet IEEE 802.3at-2009 Type 2 (PoE+). This cable can be used in rough environments.
Construction
Conductor
Stranded
Bare Cu
AWG 23/7
Drainwire
Tinned Cu
Insulation
Foamskin PE
PE 0=1.48 ± 0.02 [mm]
No. of pairs
4
Colour code
pair 1: white/blue - blue pair 2: white/orange - orange pair 3: white/green - green pair 4: white/brown - brown
Individual Screen pairs
Al/Mylar tape
Screen
Tinned Cu-braid
Inner jacket
SHF1
Ø = 9.0 [mm]
Armour
Galvanised steel wire braid
≥ 83 % [% optical cover]
Jacket
Grey
SHF1
O.D.
11.2 [mm]
Jacket marking
NEK Kabel – CAT6A Marin Armoured 4 x 2 x AWG23/7 – SHF1 – DNV – IEC 60332-3-22 – Batch no – yy/mm/dd – ****M
Specifications
Operating temperature normal
-30 – +80
Temperature @ installation
0 – +50 [°C]
Dielectric strength
DC 1kV for 1min.
Test Voltage
700
[V-AC]
Impedance at 100MHz
100 ± 5 [Ω]
Tensile strength
400 [N]
Insulation resistance
5 [GΩ x km @ 20°C]
Power over Ethernet
IEEE 802.3at-2009
Type 2 (PoE+)
Rated voltage
≥ 80 [V]
Loop resistance
150
[Ω/km]
Capacitance
≤ 45 [nF/km]
at 1kHz
Velocity factor
70 [%]
Mutual capacitance
48
[nF/km]
Min. bending radius
10 [x outer diam]
Norms
Halogenfree, max content corrosive and toxic gases
IEC 60754-2
Material properties, insulation and sheath
IEC 60092-350 & IEC 60092-350
Design and testing standards
IEC 61156-5
EN 50173
IEC 61156-5, EN 50173, EN 50228-10-2, ISO/IEC 1181 2.ed.
Flame resistance
IEC 60332-3-24
Flame retardant
IEC 60332-1-2
Toxic gases max.
IEC 61034
Smoke emission
DIN EN 61034
EN 50267
DIN EN 61034, EN 50267, EN 50399, EN 50575
Oil and fuel resistant
IEC 60811-2-1
IRM 902
4h @ 70°C
CPR classification
Dca-s1,d2,a1
Euroclass
Dca
Certification
DNV
Prod.no.
GSWB: 1089688 TCWB: 2020012
Frequency (MHz) | Attenuation (dB/100m) | NEXT (dB) | ACR (dB) | ELFEXT (dB) | Returnloss (dB/100m) |
---|---|---|---|---|---|
1 | 1.8 | 95 | 93 | 90 | 25 |
4 | 3.3 | 95 | 92 | 88 | 28 |
10 | 5.4 | 92 | 87 | 87 | 30 |
16 | 6.7 | 90 | 83 | 86 | 30 |
20 | 7.4 | 88 | 81 | 85 | 30 |
31.25 | 9.6 | 87 | 77 | 81 | 30 |
62.5 | 13.9 | 86 | 72 | 77 | 28 |
100 | 17.5 | 84 | 66 | 72 | 27 |
155 | 22.4 | 83 | 61 | 68 | 26 |
200 | 24.8 | 82 | 57 | 65 | 25 |
300 | 30.7 | 81 | 50 | 62 | 23 |
400 | 35.9 | 80 | 44 | 59 | 22 |
500 | 40.2 | 79 | 39 | 57 | 21 |
Updated
Date | Rev. | Description |
---|---|---|
03.09.2020 | 1 | Additional info. |
03.04.2023 | 2 | Additional info. |
16.10.2023 | 3 | Rated voltage |