Variant: |
Armoured marine cable for monitoring oil wells and linking PSA terminals to alarm systems, motion control and HVAC controls. Extended capability transceivers offer data rates up to 100 Mbps and up to 256 nodes, as well as 2,500 VNMS isolation and fault protection up to ±60 V. Installations up to 1,200 m.
Construction
Conductor
0.22 [mm²]
Stranded
Tinned Cu
AWG 24 (7x0.20mm)
Drain wire
0.22 mm²
Tinned Cu
Insulation
Cellular PE
No. of pairs
1, 2 or 4
Colour code
IEC 60189-2
Screen
Cu-braid
85 [% optical coverage]
Inner jacket
SHF1
Armour alt.1
Bronze wire braid
(BWB)
Armour alt.2
Tinned Cu-braid
(TWB)
Armour alt.3
Galvanised steel wire braid
(GSWB)
Jacket
Black
Halogenfree and MUD resistant thermoset compound
O.D.
See table [mm]
Weight
See table [kg/km]
Jacket marking
NEK Kabel date RS485 ARMOURED MARINE CABLE 24 AWG 120 OHM IEC 60332-3-22 CAT A-TK
Specifications
Operating temperature
-40 – +70 [°C]
Operating voltage
100
[V]
Caracteristic Impedance @ 1MHz
120 ± 15 [Ω]
Conductor resistance
<90 [Ω/km]
Insulation resistance
>1 [GΩ x km]
Test voltage
2 [kV]
Capacitance
42 [pF/km]
Min. bending radius
10 [x outer diam]
Norms
Halogenfree, max content corrosive and toxic gases
IEC 60754-1, 2
Material properties, insulation and sheath
IEC 60092-360 (359)
Design and testing standards
Work area wiring
IEC 61156-6
Flame retardant
IEC 60332-1
Fire retardant
IEC 60332-3-22 Cat.A
Smoke emission
IEC 61034-1, -2
MUD resistant
NEK TS 606
UV-resistant
ASTM G 154
Certification
DNV-GL
Number of pairs | Diam. inner jacket [mm] | Diam. outer jacket [mm] | Weight app. [kg/km] |
---|---|---|---|
1 | 5.8 | 10.5 | 200 |
2 | 7.3 | 12.2 | 230 |
4 | 8.0 | 13.0 | 270 |
Updated
Date | Rev. | Description |
---|---|---|
15.12.2015 | 2 | Norms |