Profibus DP Marin SHF2 MUD
Variant: |
Profibus data cable for communication systems and closed loop marine control systems for instruments and remote sensors, IEC 61158-2. MUD-resistant jacket.
Construction
Conductor
Stranded
Plain Cu
AWG 22/7
(0.35mm²)
Insulation
Foamskin PE
2.75 [mm]
No. of pairs
1
Colour code
Green and red
Screen
Al-polyester-Al-tape
Screen 2
Tinned Cu braid
> 80 [% optical coverage]
Inner jacket
SHF1
Outer Jacket
Black
MUD resistant SHF2
O.D.
10 [mm]
Weight
110 [kg/km]
Jacket marking
NEK KABEL PROFIBUS DP MARIN SHF2-100V-MUD DNV-GL, ABS
Specifications
Operating temperature
-40 – +90 [°C]
Characteristic impedance
@ 3-20 MHz: 150 ± 15Ω @ 38,4 kHz: 185±18,5Ω @ 9,6 kHz: 250 ± 25Ω
Conductor resistance
<55 [Ω/km]
Insulation resistance
≥ 1 [GΩ x km]
Test voltage
1000 [V-DC]
Capacitance
30 [pF/m]
Min. bending radius
10 [x outer diam]
Min. bending radius flexible
20 [x outer diam]
Norms
Halogenfree, max content corrosive and toxic gases
IEC 60754-1, 2
Material properties, insulation and sheath
IEC 60092-360 (359)
Design and testing standards
IEC 60092-350
Flame retardant
IEC 60332-1
Toxic gases max.
EN 50305 9.2
Fire retardant
IEC 60332-3-22
Ozone resistant
DIN VDE 0472 part 805 B
1483
Oil and fuel, hydrocarbons resistant
IEC 60502
DIN VDE 0472 del 803
Smoke emission
IEC 61034-1, -2
Field bus specifications
IEC 61158-2 ed. 1
MUD resistant
NEK TS 606
UV-resistant
ASTM G 154
Certification
DNV-GL, ABS
Part No.
1 pair: 1091039
2 pairs: 1091048
Attenuation nominal, max 105%
Frequency MHz | Attenuation dB/100m |
---|---|
16 | <4.5 |
4 | <2.2 |
0.038 | <0.5 |
0.0096 | <0.3 |
Updated
Date | Rev. | Description |
---|---|---|
05.12.2019 | 1 | Inner and outer jacket |