LAN cable, designed for ship- and offshore applications. Tinned Cu-connectors and braid, SHF1 jacket.
 

Construction

Conductor
0.22 [mm²]
Stranded
tinned Cu
AWG 24 (7x0.20mm)
Insulation
Foamskin PE
Ø=1,4 [mm]
No. of pairs
4
Colour code
IEC 60189-2
Individual Screen pairs
Al-/polyester tape
Screen
Tinned Cu-braid
≥80 [% coverage]
Jacket
Grey
SHF1
O.D.
8,4 [mm]
Weight
68 [kg/km]
Jacket marking
NEK Kabel - LanMarin Cat 5e S/FTP 4 x 2 x AWG24/7 - SHF1 - IEC 60332-3-22 - DD/MM/YY

Specifications

Operating temperature normal
-40 – +80 [°C]
Temperature @ installation
-20 – +60 [°C]
Test Voltage
1
[kV-DC]
(for 1 min.)
Characteristic impedance
100 ± 5 Ω
Conductor resistance
≤84 [Ω/km]
Resistance unbalance
≤5 [%]
Insulation resistance
≥ 5000 [MΩ x km]
Capacitance unbalance
≤1600
[pF/km]
@800 or 1000Hz
Min. bending radius
10 [x outer diam]

Norms

Halogenfree, max content corrosive and toxic gases
IEC 60754-1 and IEC 60754-2
Material properties, insulation and sheath
IEC 60092-360 (359)
3582
Transmission performance
IEC 61156-6
Flame resistance
IEC 60332-3-22 Cat.A
Flame retardant
IEC 60332-1-2
Sheath
3453
Smoke emission
IEC 61034-2
( ≥60% )
Oil and fuel resistant
IRM 902
23ºC / 7 days, 70°C / 4h
UV-resistant
UL 1581 (300H)
Certification
DNV
Part No.
1089606
Alt. 1 Arctic grade, 1089614
Alt. 2 MUD, 1089607

Attenuation

Freq.[MHz] Att. std [dB] Att.typ [dB] RL std [dB] RLtyp [dB] NEXTst [dB] NEXTtyp [dB] PSNEXTstd [dB] PSNEXT typ [dB] ELFEXT std [dB] ELFEXT typ [dB]
4 6,01 4,10 23,0 25,0 56,3 99,0 53,3 96,0 52,0 91,0
8 8,48 5,65 24,5 26,5 51,8 98,0 48,8 95,0 45,9 89,0
10 9,49 6,32 25,0 28,0 50,3 96,0 47,3 93,0 44,0 86,0
16 12,07 8,05 25,0 28 47,2 93,0 44,2 90,0 39,9 83,0
20 13,54 9,11 25,0 28,0 45,8 93,0 42,8 90,0 38,0 81,0
25 15,22 10,28 24,2 27,5 44,3 93,0 41,3 90,0 36,0 79,0
31,25 17,11 11,58 23,3 27,0 42,9 88,0 39,9 85,0 34,1 74,0
62,5 24,76 16,60 20,7 24,0 38,4 83,0 35,4 80,0 28,1 69,0
100 31,99 21,18 19,0 22,0 35,3 83,0 32,3 80,0 24,0 63,0

Updated

Date Rev. Description
Sept. 2016 1 Improved electrical data
24.05.2019 2 Renewal